Skip to content
HybrydaPlus
  • Kontakt
  • Informacje
  • EspHome – Yaml
    • EspHome – sprzęt All-in-One 3f
    • EspHome – DEYE 1 fazowe
    • EspHome – DEYE 3 fazowe
  • Dashboard
    • Time of Use
    • Flex Horseshoe Card – wersja 3f
  • Kontakt
  • Informacje
  • EspHome – Yaml
    • EspHome – sprzęt All-in-One 3f
    • EspHome – DEYE 1 fazowe
    • EspHome – DEYE 3 fazowe
  • Dashboard
    • Time of Use
    • Flex Horseshoe Card – wersja 3f
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
substitutions:
  modbus_controller_id: sunsynk
  settings_skipped_updates: "30"
  devicename: sunsynk
  device_description: "Sunsynk RS485 Logger"
  friendly_name: "SunSynk"
 
esphome:
  name: $devicename
  comment: '${device_description}'
 
esp32:
  board: esp32dev
  framework:
    type: arduino
 
# Enable logging
logger:
 
# Enable Home Assistant API
api:
  encryption:
    key: "Tutaj_wklej_klucz"
 
ota:
  platform: esphome
  password: "Tutaj_wklej_hasło_OTA"
 
wifi:
  ssid: Nazwa_Sieci_WiFi
  password: Hasło_sieci_WiFi
 
  # Enable fallback hotspot (captive portal) in case wifi connection fails
  ap:
    ssid: "Deyeesp32 Fallback Hotspot"
    password: "1234567890"
 
captive_portal:
 
output:
  - platform: gpio
    id: ENABLE_PIN # Enable the chip
    pin:
      number: GPIO19
      inverted: true
  - platform: gpio
    id: SE_PIN # Enable autodirection
    pin:
      number: GPIO17
      inverted: true
  - platform: gpio
    id: ENABLE_5V_PIN # Enable 5V pin for RS485 chip
    pin:
      number: GPIO16
      inverted: true
 
uart:
  id: mod_bus
  rx_pin: GPIO21
  tx_pin: GPIO22
  baud_rate: 9600
  stop_bits: 1
modbus:
  id: sunsynk_modbus
modbus_controller:
  - id: sunsynk
    address: 0x01
    modbus_id: sunsynk_modbus
    setup_priority: -10
    update_interval: "15s"
    command_throttle: "50ms"
 
switch:
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    name: "${friendly_name} Toggle Solar sell"
    register_type: holding
    address: 145
    bitmask: 1
    entity_category: config
    icon: "mdi:toggle-switch"
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid Charge"
    id: sunsynk_esphome_toggle_Grid_Charge
    register_type: holding
    address: 130
    bitmask: 1
    entity_category: config
    icon: "mdi:toggle-switch"
 
  - platform: modbus_controller  # Advanced peak shaving and valley filling function enabled
    use_write_multiple: true
    modbus_controller_id: sunsynk
    name: "${friendly_name} Toggle System Timer"
    id: sunsynk_esphome_toggle_Time_of_Use
    register_type: holding
    address: 146
    bitmask: 1
    entity_category: config
    icon: "mdi:toggle-switch"
  - platform: modbus_controller  # Time point 1 charge enable - grid charging enable
    use_write_multiple: true
    modbus_controller_id: sunsynk
    name: "${friendly_name} System Mode Grid Charge Time1"
    id: sunsynk_esphome_toggle_grid_charge_time1
    register_type: holding
    address: 172
    bitmask: 1   # 2 if you want to enable Gen charging instead
    entity_category: config
    icon: "mdi:toggle-switch"
  - platform: modbus_controller  # Time point 2 charge enable - grid charging enable
    use_write_multiple: true
    modbus_controller_id: sunsynk
    name: "${friendly_name} System Mode Grid Charge Time2"
    id: sunsynk_esphome_toggle_grid_charge_time2
    register_type: holding
    address: 173
    bitmask: 1    # 2 if you want to enable Gen charging instead
    entity_category: config
    icon: "mdi:toggle-switch"
  - platform: modbus_controller  # Time point 3 charge enable - grid charging enable
    use_write_multiple: true
    modbus_controller_id: sunsynk
    name: "${friendly_name} System Mode Grid Charge Time3"
    id: sunsynk_esphome_toggle_grid_charge_time3
    register_type: holding
    address: 174
    bitmask: 1    # 2 if you want to enable Gen charging instead
    entity_category: config
    icon: "mdi:toggle-switch"
  - platform: modbus_controller  # Time point 4 charge enable - grid charging enable
    use_write_multiple: true
    modbus_controller_id: sunsynk
    name: "${friendly_name} System Mode Grid Charge Time4"
    id: sunsynk_esphome_toggle_grid_charge_time4
    register_type: holding
    address: 175
    bitmask: 1    # 2 if you want to enable Gen charging instead
    entity_category: config
    icon: "mdi:toggle-switch"
  - platform: modbus_controller  # Time point 5 charge enable - grid charging enable
    use_write_multiple: true
    modbus_controller_id: sunsynk
    name: "${friendly_name} System Mode Grid Charge Time5"
    id: sunsynk_esphome_toggle_grid_charge_time5
    register_type: holding
    address: 176
    bitmask: 1    # 2 if you want to enable Gen charging instead
    entity_category: config
    icon: "mdi:toggle-switch"
  - platform: modbus_controller  # Time point 6 charge enable - grid charging enable
    use_write_multiple: true
    modbus_controller_id: sunsynk
    name: "${friendly_name} System Mode Grid Charge Time6"
    id: sunsynk_esphome_toggle_grid_charge_time6
    register_type: holding
    address: 177
    bitmask: 1    # 2 if you want to enable Gen charging instead
    entity_category: config
    icon: "mdi:toggle-switch"
binary_sensor:
   - platform: modbus_controller
     modbus_controller_id: sunsynk
     name: "${friendly_name} AC INV relay - do sprawdzenia" # bit 0
     id: sunsynk_esphome_AC_INV_relay_do_sprawdzenia
     register_type: holding
     address: 552
     bitmask: 0x1
   - platform: modbus_controller
     modbus_controller_id: sunsynk
     name: "${friendly_name} AC Load relay Reserved - do sprawdzenia" # bit 1
     id: sunsynk_esphome_AC_Load_relay_Reserved_do_sprawdzenia
     register_type: holding
     address: 552
     bitmask: 0x2
   - platform: modbus_controller
     modbus_controller_id: sunsynk
     name: "${friendly_name} Grid Connected Status"
     id: sunsynk_esphome_grid_connected_status
     register_type: holding
     address: 552
     bitmask: 0x4
   - platform: modbus_controller
     modbus_controller_id: sunsynk
     name: "${friendly_name} -AC Generator relay - do sprawdzenia" # bit 3
     id: sunsynk_esphome_AC_Generator_relay_do_sprawdzenia
     register_type: holding
     address: 552
     bitmask: 0x8
   - platform: modbus_controller
     modbus_controller_id: sunsynk
     name: "${friendly_name} -Turn off/on status - do sprawdzenia"   #The lower 4 bits represent the switch signal
     id: sunsynk_esphome_Turn_off_on_status_do_sprawdzenia
     register_type: holding
     address: 551
     bitmask: 0x1
text_sensor:
   - platform: modbus_controller
     modbus_controller_id: sunsynk
     id: sunsynk_esphome_overall_state
     bitmask: 0
     register_type: holding
     address: 500
     raw_encode: HEXBYTES
     name: "${friendly_name} Overall State"
     lambda: |-
       uint16_t value = modbus_controller::word_from_hex_str(x, 0);
       switch (value) {
         case 0: return std::string("standby");
         case 1: return std::string("selfcheck");
         case 2: return std::string("normal");
         case 3: return std::string("alarm");
         case 4: return std::string("fault");
         default: return std::string("----");
       }
       return x;
   - platform: template
     name: "${friendly_name} Time Slot 1"
     id: sunsynk_esphome_time_slot_1
     icon: "mdi:clock"
     lambda: |-
         int minutes, hours;
         if (id(sunsynk_esphome_system_mode_time1).state) {
         minutes = static_cast<int>(id(sunsynk_esphome_system_mode_time1).state) % 100;
         hours = static_cast<int>(id(sunsynk_esphome_system_mode_time1).state) / 100;
         } else {
           minutes = 0;
           hours = 0;
         }
         char formatted_time[6];
         snprintf(formatted_time, sizeof(formatted_time), "%02d:%02d", hours, minutes);
         return esphome::optional<std::string>(formatted_time);
   - platform: template
     name: "${friendly_name} Time Slot 2"
     id: sunsynk_esphome_time_slot_2
     icon: "mdi:clock"
     lambda: |-
         int minutes, hours;
         if (id(sunsynk_esphome_system_mode_time2).state) {
         minutes = static_cast<int>(id(sunsynk_esphome_system_mode_time2).state) % 100;
         hours = static_cast<int>(id(sunsynk_esphome_system_mode_time2).state) / 100;
         } else {
           minutes = 0;
           hours = 0;
         }
         char formatted_time[6];
         snprintf(formatted_time, sizeof(formatted_time), "%02d:%02d", hours, minutes);
         return esphome::optional<std::string>(formatted_time);
   - platform: template
     name: "${friendly_name} Time Slot 3"
     id: sunsynk_esphome_time_slot_3
     icon: "mdi:clock"
     lambda: |-
         int minutes, hours;
         if (id(sunsynk_esphome_system_mode_time3).state) {
         minutes = static_cast<int>(id(sunsynk_esphome_system_mode_time3).state) % 100;
         hours = static_cast<int>(id(sunsynk_esphome_system_mode_time3).state) / 100;
         } else {
           minutes = 0;
           hours = 0;
         }
         char formatted_time[6];
         snprintf(formatted_time, sizeof(formatted_time), "%02d:%02d", hours, minutes);
         return esphome::optional<std::string>(formatted_time);
   - platform: template
     name: "${friendly_name} Time Slot 4"
     id: sunsynk_esphome_time_slot_4
     icon: "mdi:clock"
     lambda: |-
         int minutes, hours;
         if (id(sunsynk_esphome_system_mode_time4).state) {
         minutes = static_cast<int>(id(sunsynk_esphome_system_mode_time4).state) % 100;
         hours = static_cast<int>(id(sunsynk_esphome_system_mode_time4).state) / 100;
         } else {
           minutes = 0;
           hours = 0;
         }
         char formatted_time[6];
         snprintf(formatted_time, sizeof(formatted_time), "%02d:%02d", hours, minutes);
         return esphome::optional<std::string>(formatted_time);
   - platform: template
     name: "${friendly_name} Time Slot 5"
     id: sunsynk_esphome_time_slot_5
     icon: "mdi:clock"
     lambda: |-
         int minutes, hours;
         if (id(sunsynk_esphome_system_mode_time5).state) {
         minutes = static_cast<int>(id(sunsynk_esphome_system_mode_time5).state) % 100;
         hours = static_cast<int>(id(sunsynk_esphome_system_mode_time5).state) / 100;
         } else {
           minutes = 0;
           hours = 0;
         }
         char formatted_time[6];
         snprintf(formatted_time, sizeof(formatted_time), "%02d:%02d", hours, minutes);
         return esphome::optional<std::string>(formatted_time);
   - platform: template
     name: "${friendly_name} Time Slot 6"
     id: sunsynk_esphome_time_slot_6
     icon: "mdi:clock"
     lambda: |-
         int minutes, hours;
         if (id(sunsynk_esphome_system_mode_time6).state) {
         minutes = static_cast<int>(id(sunsynk_esphome_system_mode_time6).state) % 100;
         hours = static_cast<int>(id(sunsynk_esphome_system_mode_time6).state) / 100;
         } else {
           minutes = 0;
           hours = 0;
         }
         char formatted_time[6];
         snprintf(formatted_time, sizeof(formatted_time), "%02d:%02d", hours, minutes);
         return esphome::optional<std::string>(formatted_time);
 
number:
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_Max_Sell_power
    name: "${friendly_name}-Max Sell power"
    address: 143
    unit_of_measurement: "W"
    min_value: 0
    max_value: 10000
    step: 500
    value_type: U_WORD
    mode: box
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_bat_max_charge_current
    name: "${friendly_name} Battery Max Charge current"
    address: 108
    unit_of_measurement: A
    value_type: U_WORD
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_bat_max_discharge_current
    name: "${friendly_name} Battery Max Discharge current"
    address: 109
    unit_of_measurement: A
    value_type: U_WORD
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_grid_charge_bat_current
    name: "${friendly_name} Grid Charge Battery current"
    address: 128
    unit_of_measurement: A
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_system_mode_time1
    name: "${friendly_name} System Mode Time1"
    register_type: holding
    skip_updates: ${settings_skipped_updates}
    address: 148
    icon: "mdi:clock"
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_system_mode_time2
    name: "${friendly_name} System Mode Time2"
    register_type: holding
    skip_updates: ${settings_skipped_updates}
    address: 149
    icon: "mdi:clock"
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_system_mode_time3
    name: "${friendly_name} System Mode Time3"
    register_type: holding
    skip_updates: ${settings_skipped_updates}
    address: 150
    icon: "mdi:clock"
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_system_mode_time4
    name: "${friendly_name} System Mode Time4"
    register_type: holding
    skip_updates: ${settings_skipped_updates}
    address: 151
    icon: "mdi:clock"
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_system_mode_time5
    name: "${friendly_name} System Mode Time5"
    register_type: holding
    skip_updates: ${settings_skipped_updates}
    address: 152
    icon: "mdi:clock"
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_system_mode_time6
    name: "${friendly_name} System Mode Time6"
    register_type: holding
    skip_updates: ${settings_skipped_updates}
    address: 153
    icon: "mdi:clock"
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_power_time1
    name: "${friendly_name} System Mode Power Time1"
    unit_of_measurement: W
    address: 154
    min_value: 0
    max_value: 8000
    step: 100
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_power_time2
    name: "${friendly_name} System Mode Power Time2"
    unit_of_measurement: W
    address: 155
    min_value: 0
    max_value: 8000
    step: 100
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_power_time3
    name: "${friendly_name} System Mode Power Time3"
    unit_of_measurement: W
    address: 156
    min_value: 0
    max_value: 8000
    step: 100
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_power_time4
    name: "${friendly_name} System Mode Power Time4"
    unit_of_measurement: W
    address: 157
    min_value: 0
    max_value: 8000
    step: 100
    value_type: U_WORD
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_power_time5
    name: "${friendly_name} System Mode Power Time5"
    unit_of_measurement: W
    address: 158
    min_value: 0
    max_value: 8000
    step: 100
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_power_time6
    name: "${friendly_name} System Mode Power Time6"
    unit_of_measurement: W
    address: 159
    min_value: 0
    max_value: 8000
    step: 100
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_soc_time1
    name: "${friendly_name} System Mode SoC Time1"
    unit_of_measurement: "%"
    address: 166
    min_value: 0
    max_value: 100
    step: 5
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_V_time1
    name: "${friendly_name} System Mode V Time1"
    unit_of_measurement: "V"
    address: 160
    min_value: 0000
    max_value: 6300
    step: 0.5
    value_type: U_WORD
    multiply: 100
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_soc_time2
    name: "${friendly_name} System Mode SoC Time2"
    unit_of_measurement: "%"
    address: 167
    min_value: 0
    max_value: 100
    step: 5
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_V_time2
    name: "${friendly_name} System Mode V Time2"
    unit_of_measurement: "V"
    address: 161
    min_value: 0000
    max_value: 6300
    step: 0.5
    value_type: U_WORD
    multiply: 100
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_soc_time3
    name: "${friendly_name} System Mode SoC Time3"
    unit_of_measurement: "%"
    address: 168
    min_value: 0
    max_value: 100
    step: 5
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_V_time3
    name: "${friendly_name} System Mode V Time3"
    unit_of_measurement: "V"
    address: 162
    min_value: 0000
    max_value: 6300
    step: 0.5
    value_type: U_WORD
    multiply: 100
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_soc_time4
    name: "${friendly_name} System Mode SoC Time4"
    unit_of_measurement: "%"
    address: 169
    min_value: 0
    max_value: 100
    step: 5
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_V_time4
    name: "${friendly_name} System Mode V Time4"
    unit_of_measurement: "V"
    address: 163
    min_value: 0000
    max_value: 6300
    step: 0.5
    value_type: U_WORD
    multiply: 100
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_soc_time5
    name: "${friendly_name} System Mode SoC Time5"
    unit_of_measurement: "%"
    address: 170
    min_value: 0
    max_value: 100
    step: 5
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_V_time5
    name: "${friendly_name} System Mode V Time5"
    unit_of_measurement: "V"
    address: 164
    min_value: 0000
    max_value: 6300
    step: 0.5
    value_type: U_WORD
    multiply: 100
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_soc_time6
    name: "${friendly_name} System Mode SoC Time6"
    unit_of_measurement: "%"
    address: 171
    min_value: 0
    max_value: 100
    value_type: U_WORD
 
  - platform: modbus_controller
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_set_V_time6
    name: "${friendly_name} System Mode V Time6"
    unit_of_measurement: "V"
    address: 165
    min_value: 0000
    max_value: 6300
    step: 0.5
    value_type: U_WORD
    multiply: 100
sensor:
 
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} DC Temperature"
    id: sunsynk_esphome_dc_temperature
    register_type: holding
    address: 540
    unit_of_measurement: "°C"
    value_type: S_WORD
    accuracy_decimals: 2
    filters:
      - offset: -1000
      - multiply:  0.1
 
 
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} AC Temperature"
    id: sunsynk_esphome_ac_temperature
    register_type: holding
    address: 541
    unit_of_measurement: "°C"
    value_type: S_WORD
    accuracy_decimals: 2
    filters:
      - offset: -1000
      - multiply:  0.1
 
  - platform: modbus_controller #sun12k-load frequency
    modbus_controller_id: sunsynk
    name: "${friendly_name} Load Frequency"
    id: sunsynk_esphome_load_frequency
    register_type: holding
    address: 655
    unit_of_measurement: "Hz"
    state_class: "measurement"
    accuracy_decimals: 2
    filters:
      - multiply: 0.01
    value_type: U_WORD
  - platform: modbus_controller #sun12k-inverter-frequency
    modbus_controller_id: sunsynk
    name: "${friendly_name} Inverter Frequency"
    id: sunsynk_esphome_inverter_frequency
    register_type: holding
    address: 638
    unit_of_measurement: "Hz"
    state_class: "measurement"
    accuracy_decimals: 2
    filters:
      - multiply: 0.01
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} PV1 Power"
    id: sunsynk_esphome_pv1_power
    register_type: holding
    address: 672
    unit_of_measurement: "W"
    state_class: "measurement"
    accuracy_decimals: 0
    device_class: power
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} PV2 Power"
    id: sunsynk_esphome_pv2_power
    register_type: holding
    address: 673
    unit_of_measurement: "W"
    state_class: "measurement"
    accuracy_decimals: 0
    device_class: power
    value_type: U_WORD
############################################### SOLAR TOTAL ###########################################
 
  - platform: template                   # Sum of PV1 and PV2 to get total PV Power
    name: "${friendly_name} Solar Power"
    unit_of_measurement: "W"
    accuracy_decimals: 0
    device_class: power
    state_class: measurement
    lambda: |-
      return (id(sunsynk_esphome_pv1_power).state + id(sunsynk_esphome_pv2_power).state);
    update_interval: 5s
 
#######################################################################################################
 
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} PV1 Voltage"
    id: sunsynk_esphome_pv1_voltage
    register_type: holding
    address: 676
    unit_of_measurement: "V"
    state_class: "measurement"
    accuracy_decimals: 1
    filters:
      - multiply: 0.1
    device_class: voltage
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} PV2 Voltage"
    id: sunsynk_esphome_pv2_voltage
    register_type: holding
    address: 678
    unit_of_measurement: "V"
    state_class: "measurement"
    accuracy_decimals: 1
    filters:
      - multiply: 0.1
    device_class: voltage
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} PV1 Current"
    id: sunsynk_esphome_pv1_current
    register_type: holding
    address: 677
    unit_of_measurement: "A"
    state_class: "measurement"
    accuracy_decimals: 1
    device_class: current
    filters:
      - multiply: 0.1
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} PV2 Current"
    id: sunsynk_esphome_pv2_current
    register_type: holding
    address: 679
    unit_of_measurement: "A"
    state_class: "measurement"
    accuracy_decimals: 1
    device_class: current
    filters:
      - multiply: 0.1
    value_type: U_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Day PV Energy"
    id: sunsynk_esphome_day_pv_energy
    register_type: holding
    address: 529
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 1
    filters:
      - multiply: 0.1
    value_type: U_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Total PV Energy"  #Cumulative Production
    id: sunsynk_esphome_total_pv_energy
    register_type: holding
    address: 534
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 2
    value_type: U_DWORD_R
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid Power"   # Grid side total power
    id: sunsynk_esphome_grid_power_169
    register_type: holding
    address: 625
    unit_of_measurement: "W"
    state_class: "measurement"
    device_class: power
    accuracy_decimals: 0
    value_type: S_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Day Grid Import"
    id: sunsynk_esphome_day_grid_import
    register_type: holding
    address: 520
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 1
    value_type: U_WORD
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Day Grid Export"
    id: sunsynk_esphome_day_grid_export
    register_type: holding
    address: 521
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 1
    value_type: U_WORD
    filters:
      - multiply: 0.1
 
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Day Load Power"
    id: sunsynk_esphome_day_load_power
    register_type: holding
    address: 526
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 1
    value_type: U_WORD
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Total Grid Import"
    id: sunsynk_esphome_total_grid_import
    register_type: holding
    address: 522
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 2
    value_type: U_WORD
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Total Grid Export"
    id: sunsynk_esphome_total_grid_export
    register_type: holding
    address: 524
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 2
    value_type: U_WORD
    filters:
      - multiply: 0.1
  - platform: modbus_controller #Total Consumption
    modbus_controller_id: sunsynk
    name: "${friendly_name} Total Load Energy"
    id: sunsynk_esphome_total_load_energy
    register_type: holding
    address: 527
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 2
    value_type: U_DWORD_R
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Active power generation of today"
    id: sunsynk_esphome_active_power_generation_of_today
    register_type: holding
    address: 502
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 1
    value_type: S_WORD
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid Current L1"
    id: sunsynk_esphome_grid_current_L1
    register_type: holding
    address: 630
    unit_of_measurement: "A"
    state_class: "measurement"
    accuracy_decimals: 1
    device_class: current
    filters:
      - multiply: 0.01
    value_type: S_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid Current L2"
    id: sunsynk_esphome_grid_current_L2
    register_type: holding
    address: 631
    unit_of_measurement: "A"
    state_class: "measurement"
    device_class: current
    accuracy_decimals: 1
    filters:
      - multiply: 0.01
    value_type: S_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid Current L3"
    id: sunsynk_esphome_grid_current_L3
    register_type: holding
    address: 632
    unit_of_measurement: "A"
    state_class: "measurement"
    device_class: current
    accuracy_decimals: 1
    filters:
      - multiply: 0.01
    value_type: S_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid Voltage L1"
    id: sunsynk_esphome_grid_voltage_L1
    register_type: holding
    address: 598
    unit_of_measurement: "V"
    state_class: "measurement"
    device_class: voltage
    accuracy_decimals: 1
    filters:
      - multiply: 0.1
    value_type: U_WORD    
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid Voltage L2"
    id: sunsynk_esphome_grid_voltage_L2
    register_type: holding
    address: 599
    unit_of_measurement: "V"
    state_class: "measurement"
    device_class: voltage
    accuracy_decimals: 1
    filters:
      - multiply: 0.1
    value_type: U_WORD    
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid Voltage L3"
    id: sunsynk_esphome_grid_voltage_L3
    register_type: holding
    address: 600
    unit_of_measurement: "V"
    state_class: "measurement"
    device_class: voltage
    accuracy_decimals: 1
    filters:
      - multiply: 0.1
    value_type: U_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid CT L1 Power"
    id: sunsynk_esphome_grid_ct_L1_power
    register_type: holding
    address: 604
    unit_of_measurement: "W"
    state_class: "measurement"
    device_class: power
    accuracy_decimals: 0
    value_type: S_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid CT L2 Power"
    id: sunsynk_esphome_grid_ct_L2_power
    register_type: holding
    address: 605
    unit_of_measurement: "W"
    state_class: "measurement"
    device_class: power
    accuracy_decimals: 0
    value_type: S_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid CT L3 Power"
    id: sunsynk_esphome_grid_ct_L3_power
    register_type: holding
    address: 606
    unit_of_measurement: "W"
    state_class: "measurement"
    device_class: power
    accuracy_decimals: 0
    value_type: S_WORD  
  - platform: modbus_controller  # Grid internal - total active power
    modbus_controller_id: sunsynk
    name: "${friendly_name} Internal total Power do sprawdzenia"
    id: sunsynk_esphome_Internal_total_Power_do_sprawdzenia
    register_type: holding
    address: 607
    unit_of_measurement: "W"
    state_class: "measurement"
    accuracy_decimals: 0
    value_type: S_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} External CT L1 Power"
    id: sunsynk_esphome_External_CT_L1_Power
    register_type: holding
    address: 616
    unit_of_measurement: "W"
    state_class: "measurement"
    accuracy_decimals: 0
    value_type: S_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} External CT L2 Power"
    id: sunsynk_esphome_External_CT_L2_Power
    register_type: holding
    address: 617
    unit_of_measurement: "W"
    state_class: "measurement"
    accuracy_decimals: 0
    value_type: S_WORD  
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} External CT L3 Power"
    id: sunsynk_esphome_External_CT_L3_Power
    register_type: holding
    address: 618
    unit_of_measurement: "W"
    state_class: "measurement"
    accuracy_decimals: 0
    value_type: S_WORD    
  - platform: modbus_controller  
    modbus_controller_id: sunsynk
    name: "${friendly_name} Grid LD Power 167"
    id: sunsynk_esphome_grid_power_167
    register_type: holding
    address: 619
    unit_of_measurement: "W"
    state_class: "measurement"
    device_class: power
    accuracy_decimals: 0
    value_type: S_WORD
  - platform: modbus_controller # Load totalpower
    modbus_controller_id: sunsynk
    name: "${friendly_name} Load Power"
    id: sunsynk_esphome_load_power
    register_type: holding
    address: 653
    unit_of_measurement: "W"
    state_class: "measurement"
    accuracy_decimals: 0
    value_type: S_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Warning1"
    id:  sunsynk_esphome_Warning1
    register_type: holding
    address: 553
    accuracy_decimals: 0
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Warning2"
    id:  sunsynk_esphome_Warning2
    register_type: holding
    address: 554
    accuracy_decimals: 0
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Warning3"
    id:  sunsynk_esphome_Warning3
    register_type: holding
    address: 555
    accuracy_decimals: 0
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Error1"
    id:  sunsynk_esphome_Error1
    register_type: holding
    address: 556
    accuracy_decimals: 0
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Error2"
    id:  sunsynk_esphome_Error2
    register_type: holding
    address: 557
    accuracy_decimals: 0
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Error3"
    id:  sunsynk_esphome_Error3
    register_type: holding
    address: 558
    accuracy_decimals: 0
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Failure status of communication board"
    id:  sunsynk_esphome_Failure_status_of_communication_board
    register_type: holding
    address: 548
    accuracy_decimals: 0
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Minimum insulation impedance"
    id:  sunsynk_esphome_Minimum_insulation_impedance
    register_type: holding
    unit_of_measurement: "kΩ"
    state_class: "measurement"
    address: 65
    accuracy_decimals: 0
    value_type: U_WORD
    filters:
      - multiply: 0.1
# Batteri
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Day Battery Charge"
    id:  ssunsynk_esphome_day_battery_charge
    register_type: holding
    address: 514
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 1
    value_type: U_WORD
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Day Battery Discharge"
    id:  sunsynk_esphome_day_battery_discharge
    register_type: holding
    address: 515
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 1
    value_type: U_WORD
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Total Battery Charge"
    id:  sunsynk_esphome_total_battery_charge
    register_type: holding
    address: 516
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 1
    value_type: U_DWORD_R
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Total Battery Discharge"
    id:  sunsynk_esphome_total_battery_discharge
    register_type: holding
    address: 518
    unit_of_measurement: "kWh"
    state_class: "total_increasing"
    device_class: energy
    accuracy_decimals: 1
    value_type: U_DWORD_R
    filters:
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Battery Temperature"
    id:  sunsynk_esphome_battery_temperature
    register_type: holding
    address: 586
    unit_of_measurement: "°C"
    accuracy_decimals: 1
    device_class: temperature
    value_type: U_WORD
    filters:
      - offset: -1000
      - multiply: 0.1
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Battery Voltage"
    id: sunsynk_esphome_battery_voltage
    register_type: holding
    address: 587  
    unit_of_measurement: "V"
    state_class: "measurement"
    accuracy_decimals: 1
    device_class: voltage
    filters:
      - multiply: 0.01
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Battery SOC"
    id: sunsynk_esphome_battery_soc
    register_type: holding
    address: 588
    unit_of_measurement: "%"
    state_class: "measurement"
    accuracy_decimals: 0
    device_class: battery
    value_type: U_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Battery Power"
    id: sunsynk_esphome_battery_power
    register_type: holding
    address: 590
    unit_of_measurement: "W"
    state_class: "measurement"
    device_class: power
    accuracy_decimals: 0
    value_type: S_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} Battery Current"
    id: sunsynk_esphome_battery_currentt
    register_type: holding
    address: 591
    unit_of_measurement: "A"
    state_class: "measurement"
    device_class: current
    accuracy_decimals: 1
    filters:
      - multiply: 0.01
    value_type: S_WORD
  - platform: modbus_controller
    modbus_controller_id: sunsynk
    name: "${friendly_name} The corrected capacity of the battery"
    id: sunsynk_esphome_The_corrected_capacity_of_the_battery
    register_type: holding
    address: 592
    unit_of_measurement: "Ah"
    state_class: "measurement"
    accuracy_decimals: 0
    value_type: U_WORD
 
################################################ SELECT SENSORS ################################################
 
select:
  - platform: modbus_controller                   #141 Select Energy Patern
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_select_energy_pattern
    name: "${friendly_name} Energy Pattern"
    address: 141
    value_type: U_WORD
    optionsmap:
      "Battery first": 0
      "Load first": 1  
        
  - platform: modbus_controller                   #142 Select Work Mode
    use_write_multiple: true
    modbus_controller_id: sunsynk
    id: sunsynk_esphome_select_work_mode
    name: "${friendly_name} Work Mode"
    address: 142
    value_type: U_WORD
    optionsmap:
      "Selling First": 0
      "Zero Export + Limit to Load Only": 1
      "Limited to Home": 2    

Całość w trzech krokach

  • 1. Serwer HA
  • 2. Komunikacja modbus:
    • All-in-One
      • Kod EspHome 3f
    • Esp32 + TTL <=> RS485
      • Kod EspHome 1f
      • Kod EspHome 3f
  • 3. Dashboard

Ostatni wpis

  • Tani licznik energii z Modbus do Home Assistant – EA777 (EARU)8 lutego, 2026
  • Ratowanie głęboko rozładowanej baterii w falownikach Deye LV (48 V)11 stycznia, 2026
  • Lumina Energy Card – ciekawy panel.30 grudnia, 2025
  • Ładowanie magazynu energii z sieci krok po kroku (taryfa G12).28 grudnia, 2025
  • Jak prawidłowo rozszerzać systemy bateryjne Deye ESS? Praktyczny przewodnik dla instalatorów (2025)3 grudnia, 2025

Archiwum

  • luty 2026 (1)
  • styczeń 2026 (1)
  • grudzień 2025 (3)
  • październik 2025 (1)
  • wrzesień 2025 (1)
  • czerwiec 2025 (2)
  • marzec 2025 (2)
  • luty 2025 (2)
  • listopad 2024 (2)
  • wrzesień 2024 (1)
  • czerwiec 2024 (2)
  • maj 2024 (1)
  • kwiecień 2024 (3)
  • marzec 2024 (2)
  • styczeń 2024 (3)
  • październik 2023 (3)
  • wrzesień 2023 (10)

Kategorie

  • Dashboard
  • DEYE
  • HA
  • Inne
  • Komunikacja
  • Ustawienia Deye
2015 - 2022 © Powered by Theme Vision.